Electric surgery high frequency device "FOTEK". Model E352M
- standard modes set with the ability to set the power. Additional specialized mode for operation in liquid media TUR/VAP.
- possibility to set up 4 modes simultaneously: monopolar and bipolar cutting, monopolar and bipolar coagulation
- automatic stop of coagulation process in bipolar modes
- intended for use in extensive and complex operations
APPLICATION FIELDS:
- general surgery
- abdominal surgery
- plastic surgery
- neurosurgery
- cardiac surgery
- vascular surgery
- urology
- TUR
- gynecology and vaginal surgery
- oncology
- endoscopy
- laparoscopy
- thoracic surgery
- maxillofacial surgery
- hysteresectoscopy
- dermatocosmetology
- ENT
- ophthalmology
- traumatology
- purulent surgery
| OPERATION MODES: | |
| MONOPOLAR CUTTING | |
|
|
|
|
CUT monopolar cutting without sparking and pronounced coagulation
|
|
BLEND monopolar cutting with moderate sparking and thin layer of coagulation
|
|
BLEND 1 monopolar cutting with strong sparking and with a pronounced layer of coagulation
|
|
TUR/VAP monopolar cutting with coagulation and monopolar vaporization of soft tissues in dry and liquid media
|
| MONOPOLAR COAGULATION | |
|
SOFT monopolar contact coagulation without sparking, carbonization and with a smooth increase in the thickness of the coagulated tissue up to 5 mm
|
|
FORCE monopolar forced coagulation with strong spark generation and rapid formation of coagulated tissue layer
|
|
FULGUR monopolar forced non-contact coagulation with strong sparking, rapid formation of coagulated tissue layer and the possibility of contact cutting with pronounced coagulation |
|
SPRAY monopolar non-contact coagulation with strong sparking and smooth increase in the thickness of the coagulated tissue layer
|
|
BIPOLAR MODES |
|
|
BI-COAG bipolar coagulation without sparking and tissue carbonization
|
|
BI-BLEND bipolar cutting with coagulation, mild sparking
|
|
BI-AUTO-STOP bipolar coagulation without sparking with automatic stop of the high-frequency current supply to the instrument as the coagulation completed
|
|
BI-AUTO-START/STOP bipolar coagulation without sparking with automatic start of the high-frequency current supply to the instrument when tissue is grasped and automatic stop when coagulation is completed |
MONOPOLAR
- double-pedal footswitch
- control buttons on the holders of monopolar electrodes
- single-pedal bipolar footswitch
-
blue pedal on double-pedal footswitch with monopolar coagulation modes turned off (optional)





